RP - Tech Knowledgebase
Monday, 4 August 2014
Thursday, 9 August 2012
Automatic Water-Level Indicator
This
water-level indicator uses a 7-segment display, instead of LEDs, to indicate
the water level (low, half and full) in the tank. Moreover, a buzzer is used to
alert you of water overflowing from the tank. The circuit shows the water level
by displaying L, H and F for low, half and full, respectively. The circuit uses
five sensors to sense the different water levels in the tank. Sensor A is
connected to the negative terminal (GND) of the power supply. The other four
sensors (B through E) are connected to the inputs of NOT gate IC 7404. When
there is a high voltage at the input pin of the NOT gate, it outputs a low
voltage. Similarly, for a low voltage at the input pin of the NOT gate, it
outputs a high voltage.
When the tank is empty, the input pins of IC 7404 are pulled high via a
1-mega-ohm resistor. So it outputs a low voltage. As water starts filling the
tank, a low voltage is available at the input pins of the gate and it outputs a
high voltage. When the water in the tank rises to touch the low level, there
is
a low
voltage at input pin 5 of gate N3 and high output at pin 6. Pin 6 of the gate
is connected to pin 10 of gate N9, so pin 10 also goes high. Now as both pins 9
and 10 of gate N9 are high, its output pin 8 also goes high. As a result,
positive supply is applied to DIS3 and it shows ‘L’ indicating low level of
water in the tank. Similarly, when water in the tank touches the half level,
pins 4 and 5 of AND gate N8 become high.
As a result, its output also goes high and
DIS2 shows ‘H’ indicating half level of water in the tank. At this time, pin 9
of gate N9 also goes low via gate N4 and DIS3 stops glowing. When the water
tank becomes full, the voltage at pin 1 of gate N1 and pin 3 of gate N2 goes
low. Output pin 3 of gate N7 goes high and DIS1 shows ‘F’ indicating that the
water tank is full. When water starts overflowing the tank, pin 13 of gate N6
goes low to make output pin 12.
The buzzer sounds to indicate that water is overflowing the tank and you need
to switch off the motor pump. Assemble the circuit on a general-purpose PCB and
enclose in a suitable box. Use a non-corrosive material such as steel strip for
the five sensors and hang them in the water tank as shown in the circuit
diagram. Use regulated 5V to power the circuit.
Monday, 30 July 2012
Automatic Phase Changer
In
three-phase applications, if low voltage is available in any one or two
phases, and you want your equipment to work on normal voltage, this
circuit will solve your problem. However, a proper-rating fuse needs to
be used in the input lines (R, Y and B) of each phase. The circuit
provides correct voltage in the same power supply lines through relays
from the other phase where correct voltage is available. Using it you
can operate all your equipment even when correct voltage is available on
a single phase in the building.
The
circuit is built around a transformer, comparator, transistor and
relay. Three identical sets of this circuit, one each for three phases,
are used. Let us now consider the working of the circuit connecting red
cable (call it ‘R’ phase).
The
mains power supply phase R is stepped down by transformer X1 to deliver
12V, 300 mA, which is rectified by diode D1 and filtered by capacitor
C1 to produce the operating voltage for the operational amplifier (IC1).
The voltage at inverting pin 2 of oprational amplifier IC1 is taken
from the voltage divider circuit of resistor R1 and preset resistor VR1.
VR1 is used to set the reference voltage according to the requirement.
The reference voltage at non-inverting pin 3 is fixed to 5.1V through
zener diode ZD1.
Till
the supply voltage available in phase R is in the range of 200V-230V,
the voltage at inverting pin 2 of IC1 remains high, i.e., more than
reference voltage of 5.1V, and its output pin 6 also remains high. As a
result, transistor T1 does not conduct, relay RL1 remains de-energised
and phase ‘R’ supplies power to load L1 via normally closed(N/C) contact
of relay RL1.As soon as phase-R voltage goes below 200V, the voltage at
inverting pin 2 of IC1 goes below reference voltage of 5.1V, and its
output goes low.As a result, transistor T1 conducts and relay RL1
energises and load L1 is disconnected from phase ‘R’ and connected to
phase ‘Y’ through relay RL2.Similarly, the auto phase-change of the
remaining two phases, viz, phase‘Y’ and phase ‘B,’ can be
explained.Switch S1 is mains power ‘on’/’off’ switch.
Use relay contacts of proper rating and fuses should be able to take-on the load when transferred from other phases. While wiring, assembly and installation of the circuit, make sure that you:
1. Use good-quality, multi-strand insulated copper wire suitable for your current requirement.
2. Use good-quality relays with proper contact and current rating.
3. Mount the transformer(s) and relays on a suitable cabinet. Use a Tag Block(TB) for incoming/out going connections from mains.
1. Use good-quality, multi-strand insulated copper wire suitable for your current requirement.
2. Use good-quality relays with proper contact and current rating.
3. Mount the transformer(s) and relays on a suitable cabinet. Use a Tag Block(TB) for incoming/out going connections from mains.
Saturday, 28 July 2012
IR Reciver&Transmitter
Using
this circuit, audio musical notes can be generated and heard up to a
distance of 10 metres. The circuit can be divided into two
parts: IR music transmitter and receiver. The IR music transmitter
works off a 9V battery, while the IR music receiver works off regulated
9V to 12V. Fig. 1 shows the circuit of the IR music transmitter. It uses
popular melody generator IC UM66 (IC1) that can continuously generate musical tones. The
output of IC1 is fed to the IR driver stage (built across the
transistors T1 and T2) to get the maximum range. Here the red LED (LED1)
flickers according
to the musical tones generated by UM66 IC, indicating modulation. IR
LED2 and LED3 are infrared transmitting LEDs. For maximum sound transmission these should be oriented towards IR phototransistor L14F1 (T3).
The
IR music receiver uses popular op-amp IC µA741 and audio-frequency
amplifier IC LM386 along with phototransistor L14F1 and some discrete
components (Fig. 2). The melody generated by IC UM66 is transmitted
through IR LEDs, received by phototransistor T3 and fed to pin 2 of IC
µA741 (IC2). Its gain can be varied using potmeter VR1. The output of IC
µA741 is fed to IC LM386 (IC3) via capacitor C5 and potmeter VR2. The
melody produced is heard through the receiver’s loudspeaker. Potmeter
VR2 is used to control the volume of loudspeaker LS1(8ohm, 1W).
Switching off the power supply stops melody generation.
Monday, 23 July 2012
Diodes
In electronics, a diode is a two-terminal electronic component with asymmetric transfer characteristic, with low (ideally zero) resistance to current flow in one direction, and high (ideally infinite) resistance in the other. A semiconductor diode, the most common type today, is a crystalline piece of semiconductor material with a p-n junction connected to two electrical terminals. A vacuum tube diode, now rarely used except in some high-power technologies and by enthusiasts, is a vacuum tube with two electrodes, a plate (anode) and cathode.
The most common function of a diode is to allow an electric current to pass in one direction (called the diode's forward direction), while blocking current in the opposite direction (the reverse direction). Thus, the diode can be viewed as an electronic version of a check valve. This unidirectional behavior is called rectification, and is used to convert alternating current to direct current, including extraction of modulation from radio signals in radio receivers—these diodes are forms of rectifiers.
Friday, 20 July 2012
Induction Motor
TYPES OF DC MOTORS
Stepper Motor
Brushed DC Motor
Brushless DC Motor (BLDC)
Permanent Magnet Synchronous Motor
Stepper Motor:
A stepper motor (or step motor) is a brushless DC electric motor that divides a full rotation into a number of equal steps.
The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application.
Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.
Subscribe to:
Posts (Atom)